SWP_B universal couplingBefore installation, clean the anti-rust grease on the flange joint surface, which may reduce the friction of the contact surface or reduce the unfavorable factors of the contact area of the joint surface.
Long-term overloading of universal couplings and operation accidents should be avoided.
After working with load for one shift, check whether the connecting bolts of the universal joint flange are loose, and tighten them again with the specified tightening torque. Repeat this for several shifts until the tightening force is in a stable state.
The joint bearings and spline pairs of the SWP_B universal coupling should be greased every 1-2 weeks under high temperature working conditions. Under general working conditions, grease should be added every 500 hours of continuous work, under intermittent working conditions , Grease once every three months, the grease grade adopts No. 2 industrial lithium grease.
During work and operation, you should always observe whether the cardan shaft universal joint has abnormal radial swing and bearing heating. If these phenomena are found, repair them in time.